SCSI External DB25 Female
Pin |
Name |
Direction |
Description |
1
|
/REQ
|
OUT
|
Request
|
2
|
/MSG
|
OUT
|
Message
|
3
|
I/O
|
OUT
|
Input/Output
|
4
|
/RST
|
IN/OUT
|
Reset
|
5
|
/ACK
|
IN
|
Acknowledge
|
6
|
BSY
|
IN/OUT
|
Busy
|
7
|
GND
|
------
|
Ground
|
8
|
DB0
|
IN/OUT
|
Data Bus 0
|
9
|
GND
|
------
|
Ground
|
10
|
DB3
|
IN/OUT
|
Data Bus 3
|
11
|
DB5
|
IN/OUT
|
Data Bus 5
|
12
|
DB6
|
IN/OUT
|
Data Bus 6
|
13
|
DB7
|
IN/OUT
|
Data Bus 7
|
14
|
GND
|
------
|
Ground
|
15
|
C/D
|
OUT
|
Control/Data
|
16
|
GND
|
------
|
Ground
|
17
|
/ATN
|
IN
|
Attention
|
18
|
GND
|
------
|
Ground
|
19
|
/SEL
|
IN/OUT
|
Select
|
20
|
PARITY
|
IN/OUT
|
Data Parity
|
21
|
DB1
|
IN/OUT
|
Data Bus 1
|
22
|
DB2
|
IN/OUT
|
Data Bus 2
|
23
|
DB4
|
IN/OUT
|
Data Bus 4
|
24
|
GND
|
------
|
Ground
|
25
|
TMPWR
|
IN/OUT
|
Termination Power
|
SCSI DB25 to High Density DB50 Adapter
Description |
DB25
|
High Density DB50
|
Request |
1 |
49 |
Message |
2 |
46 |
Input/Output |
3 |
50 |
Reset |
4 |
45 |
Acknowledge |
5 |
44 |
Busy |
6 |
43 |
Data Bus 0 |
8 |
26 |
Data Bus 3 |
10 |
29 |
Data Bus 5 |
11 |
31 |
Data Bus 6 |
12 |
32 |
Data Bus 7 |
13 |
33 |
Control/Data |
15 |
48 |
Attention |
17 |
41 |
Select |
19 |
47 |
Data Parity |
20 |
34 |
Data Bus 1 |
21 |
27 |
Data Bus 2 |
22 |
28 |
Data Bus 4 |
23 |
30 |
Termination Power |
25 |
38 |
All the unused pins at the DB25 end should be connected to pins 1-25 at the High-Density DB50
SCSI 50 Pin M Internal Normal
Pin
|
Name
|
Direction
|
Description
|
2
|
DB0
|
IN/OUT
|
Data Bus 0
|
4
|
DB1
|
IN/OUT
|
Data Bus 1
|
6
|
DB2
|
IN/OUT
|
Data Bus 2
|
8
|
DB3
|
IN/OUT
|
Data Bus 3
|
10
|
DB4
|
IN/OUT
|
Data Bus 4
|
12
|
DB5
|
IN/OUT
|
Data Bus 5
|
14
|
DB6
|
IN/OUT
|
Data Bus 6
|
16
|
DB7
|
IN/OUT
|
Data Bus 7
|
18
|
PARITY
|
IN/OUT
|
Data Parity (odd Parity)
|
20
|
GND
|
------
|
Ground
|
22
|
GND
|
------
|
Ground
|
24
|
GND
|
------
|
Ground
|
26
|
TMPWR
|
IN/OUT
|
Termination Power
|
28
|
GND
|
------
|
Ground
|
30
|
GND
|
------
|
Ground
|
32
|
/ATN
|
IN
|
Attention
|
34
|
GND
|
------
|
Ground
|
36
|
/BSY
|
IN/OUT
|
Busy
|
38
|
/ACK
|
IN
|
Acknowledge
|
40
|
/RST
|
IN/OUT
|
Reset
|
42
|
/MSG
|
OUT
|
Message
|
44
|
/SEL
|
IN/OUT
|
Select
|
46
|
/C/D
|
OUT
|
Control/Data
|
48
|
/REQ
|
OUT
|
Request
|
50
|
/I/O
|
OUT
|
Input/Output
|
SCSI 68 Pin Normal
Pin |
Name |
Direction |
Description |
1 |
GND |
------ |
Ground |
2 |
GND |
------ |
Ground |
3 |
GND |
------ |
Ground |
4 |
GND |
------ |
Ground |
5 |
GND |
------ |
Ground |
6 |
GND |
------ |
Ground |
7 |
GND |
------ |
Ground |
8 |
GND |
------ |
Ground |
9 |
GND |
------ |
Ground |
10 |
GND |
------ |
Ground |
11 |
GND |
------ |
Ground |
12 |
GND |
------ |
Ground |
13 |
GND |
------ |
Ground |
14 |
GND |
------ |
Ground |
15 |
GND |
------ |
Ground |
16 |
GND |
------ |
Ground |
17 |
TERMPWR |
IN/OUT |
Termination Power |
18 |
TERMPWR |
IN/OUT |
Termination Power |
19 |
RES |
------ |
Reserved |
20 |
GND |
------ |
Ground |
21 |
GND |
------ |
Ground |
22 |
GND |
------ |
Ground |
23 |
GND |
------ |
Ground |
24 |
GND |
------ |
Ground |
25 |
GND |
------ |
Ground |
26 |
GND |
------ |
Ground |
27 |
GND |
------ |
Ground |
28 |
GND |
------ |
Ground |
29 |
GND |
------ |
Ground |
30 |
GND |
------ |
Ground |
31 |
GND |
------ |
Ground |
32 |
GND |
------ |
Ground |
33 |
GND |
------ |
Ground |
34 |
GND |
------ |
Ground |
35 |
-DB12 |
IN/OUT |
-Data Bus 12 |
36 |
-DB13 |
IN/OUT |
-Data Bus 13 |
37 |
-DB14 |
IN/OUT |
-Data Bus 14 |
38 |
-DB15 |
IN/OUT |
-Data Bus 15 |
39 |
-DPB1 |
IN/OUT |
-Data Bus Parity (odd Parity) |
40 |
-DB0 |
IN/OUT |
-Data Bus 0 |
41 |
-DB1 |
IN/OUT |
-Data Bus 1 |
42 |
-DB2 |
IN/OUT |
-Data Bus 2 |
43 |
-DB3 |
IN/OUT |
-Data Bus 3 |
44 |
-DB4 |
IN/OUT |
-Data Bus 4 |
45 |
-DB5 |
IN/OUT |
-Data Bus 5 |
46 |
-DB6 |
IN/OUT |
-Data Bus 6 |
47 |
-DB7 |
IN/OUT |
-Data Bus 7 |
48 |
-DPB |
IN/OUT |
-Data Bus Parity (odd Parity) |
49 |
GND |
------ |
Ground |
50 |
GND |
------ |
Ground |
51 |
TERMPWR |
IN/OUT |
Termination Power |
52 |
TERMPWR |
IN/OUT |
Termination Power |
53 |
RES |
------ |
Reserved |
54 |
GND |
------ |
Ground |
55 |
-ATN |
IN |
-Attention |
56 |
GND |
------ |
Ground |
57 |
-BSY |
IN/OUT |
-Bus is busy |
58 |
-ACK |
IN |
-Acknowledge |
59 |
-RST |
IN/OUT |
-Reset |
60 |
-MSG |
OUT |
-Message |
61 |
-SEL |
IN/OUT |
-Select |
62 |
-C/D |
OUT |
-Control or Data |
63 |
-REQ |
OUT |
-Request |
64 |
-I/O |
OUT |
-In/Out |
65 |
-DB8 |
IN/OUT |
-Data Bus 8 |
66 |
-DB9 |
IN/OUT |
-Data Bus 9 |
67 |
-DB10 |
IN/OUT |
-Data Bus 10 |
68 |
-DB11 |
IN/OUT |
-Data Bus 11 |
SCSI 68 Pin Differential
Pin |
Name |
Dir |
Description |
1 |
+DB12 |
IN/OUT |
+Data Bus 12 |
2 |
+DB13 |
IN/OUT |
+Data Bus 13 |
3 |
+DB14 |
IN/OUT |
+Data Bus 14 |
4 |
+DB15 |
IN/OUT |
+Data Bus 15 |
5 |
+DPB1 |
IN/OUT |
+Data Bus Parity (odd Parity) |
6 |
GND |
------ |
Ground |
7 |
+DB0 |
IN/OUT |
+Data Bus 0 |
8 |
+DB1 |
IN/OUT |
+Data Bus 1 |
9 |
+DB2 |
IN/OUT |
+Data Bus 2 |
10 |
+DB3 |
IN/OUT |
+Data Bus 3 |
11 |
+DB4 |
IN/OUT |
+Data Bus 4 |
12 |
+DB5 |
IN/OUT |
+Data Bus 5 |
13 |
+DB6 |
IN/OUT |
+Data Bus 6 |
14 |
+DB7 |
IN/OUT |
+Data Bus 7 |
15 |
+DPB |
IN/OUT |
+Data Bus Parity (odd Parity) |
16 |
DIFFSENSE |
? |
? |
17 |
TERMPWR |
IN/OUT |
Termination Power |
18 |
TERMPWR |
IN/OUT |
Termination Power |
19 |
RES |
------ |
Reserved |
20 |
+ATN |
IN |
+Attention |
21 |
GND |
------ |
Ground |
22 |
+BSY |
IN/OUT |
+Bus is busy |
23 |
+ACK |
IN |
+Acknowledge |
24 |
+RST |
IN/OUT |
+Reset |
25 |
+MSG |
OUT |
+Message |
26 |
+SEL |
IN/OUT |
+Select |
27 |
+C/D |
OUT |
+Control or Data |
28 |
+REQ |
OUT |
+Request |
29 |
+I/O |
OUT |
+In/Out |
30 |
GND |
------ |
Ground |
31 |
+DB8 |
IN/OUT |
+Data Bus 8 |
32 |
+DB9 |
IN/OUT |
+Data Bus 9 |
33 |
+DB10 |
IN/OUT |
+Data Bus 10 |
34 |
+DB11 |
IN/OUT |
+Data Bus 11 |
35 |
-DB12 |
IN/OUT |
-Data Bus 12 |
36 |
-DB13 |
IN/OUT |
-Data Bus 13 |
37 |
-DB14 |
IN/OUT |
-Data Bus 14 |
38 |
-DB15 |
IN/OUT |
-Data Bus 15 |
39 |
-DPB1 |
IN/OUT |
-Data Bus Parity (odd Parity) |
40 |
GND |
------ |
Ground |
41 |
-DB0 |
IN/OUT |
-Data Bus 0 |
42 |
-DB1 |
IN/OUT |
-Data Bus 1 |
43 |
-DB2 |
IN/OUT |
-Data Bus 2 |
44 |
-DB3 |
IN/OUT |
-Data Bus 3 |
45 |
-DB4 |
IN/OUT |
-Data Bus 4 |
46 |
-DB5 |
IN/OUT |
-Data Bus 5 |
47 |
-DB6 |
IN/OUT |
-Data Bus 6 |
48 |
-DB7 |
IN/OUT |
-Data Bus 7 |
49 |
-DPB |
IN/OUT |
-Data Bus Parity (odd Parity) |
50 |
GND |
------ |
Ground |
51 |
TERMPWR |
IN/OUT |
Termination Power |
52 |
TERMPWR |
IN/OUT |
Termination Power |
53 |
RES |
------ |
Reserved |
54 |
-ATN |
IN |
-Attention |
55 |
GND |
------ |
Ground |
56 |
-BSY |
IN/OUT |
-Bus is busy |
57 |
-ACK |
IN |
-Acknowledge |
58 |
-RST |
IN/OUT |
-Reset |
59 |
-MSG |
OUT |
-Message |
60 |
-SEL |
IN/OUT |
-Select |
61 |
-C/D |
OUT |
-Control or Data |
62 |
-REQ |
OUT |
-Request |
63 |
-I/O |
OUT |
-In/Out |
64 |
GND |
------ |
Ground |
65 |
-DB8 |
IN/OUT |
-Data Bus 8 |
66 |
-DB9 |
IN/OUT |
-Data Bus 9 |
67 |
-DB10 |
IN/OUT |
-Data Bus 10 |
68 |
-DB11 |
IN/OUT |
-Data Bus 11 |